SILENT TYPE DIESEL GENERATOR SETS--YANGDONG SERIES

Product Description

 

GENERATOR SETS POWERED BY YANGDONG ENGINE


MAIN SPECIFICATION OF DIESEL GENERATOR SETS (50HZ)
GENSET
MODEL
Open type model GDYD10 GDYD11 GDYD15 GDYD18 GDYD20 GDYD25 GDYD25 GDYD28 GDYD30 GDYD31 GDYD33 GDYD38 GDYD43 GDYD50 GDYD56 GDYD63 GDYD80
Soundproof model GDYD10S GDYD11S GDYD15S GDYD18S GDYD20S GDYD25S GDYD25S GDYD28S GDYD30S GDYD31S GDYD33S GDYD38S GDYD43S GDYD50S GDYD56S GDYD63S GDYD80S
Prime output(kVA/kW) 10/8 11/8.8 15/12 17.5/14 20/16 25/20 25/20 27.5/22 30/24 31.3/25 32.5/26 37.5/30 42.5/34 50/40 56.25/45 62.5/50 80/64
Standby output (kVA/kW) 11/8.8 12.1/9.68 16.5/13.2 19.25/15.4 22/17.6 27.5/22 27.5/22 30.25/23.2 33/26.4 34.43/27.5 35.75/28.6 41.25/33 46.75/37.3 55/44 61.875/49.5 68.75/55 88/70.4


TECHNICAL DATA
DIESEL ENGINE MODEL YD380D YD385D YD480D YND485D YSD490D YND485ZLD Y490D Y495D Y4100D YSD490ZLD Y4102D Y4105D Y4110D Y4102ZLD Y4105ZLD YD4EZLD Y4110ZLD
ENGINE CHARACTERS Water-cooled,in line,direct injection,wet cylinder liner,1500rpm
Prime Output (KW) 10 11 14 17 21 25 24 27 30 32 33 38 43 48 55 63 80
Aspiration N T&I
NO. of Cylinder 3 4
Bore x Stroke (mm) 80x90 85*90 80*90 85*95 90*100 85*95 90*105 95*105 100*118 90*100 102x118 105*118 108X118 102*118 105*118 110X118
Displacement (L) 1.357  1.532  1.809  2.156  2.540  2.156  2.670  2.977  3.7  2.543  3.875  4.1  4.324  3.875  4.1  4.4 
Compression Ratio 18:01
Rated Fuel Consumption@100% Load (L/h) 2.4  2.6  3.34  3.6  3.7  4.5  4.5  6.0  6.7  6.7  6.9  8.29  8.7  10  12.5  14  16 
Alternator Model JDG164B JDG164B JDG164D JDG184E JDG184E JDG184F JDG184F JDG184F JDG184G JDG184G JDG184H JDG184H JDG224C JDG224D JDG224ES JDG224E JDG224GS
Prime Output (kVA/kW) 11/8.8 11/8.8 16/12.8 22.5/18 22.5/18 27.5/22 27.5/22 27.5/22 31.3/25 31.3/25 37.5/30 37.5/30 42.5/34 50/40 56.25/45 62.5/50 80/64
Power Efficiency 79.8% 79.8% 81.9% 85.3% 85.3% 86.5% 86.5% 86.5% 87.3% 87.3% 86.9% 86.9% 87.4% 88.5% 89.1% 89.1% 90.4%
CHARACTERS 4 Pole, Rotating Field,Brushless, Self excited,H class insulation,IP22,AVR460/440 ,12 WINDING LEADS.
Voltage Regulation ±1.0% with4% engine governing
Open Type Dimensions
(LXWXH) m
1250×570×920 1400×570×1000 1500×650×1070 1700×810×1070 1850×810×1150 1950×810×1150
Weight (KG) (2)  320 390 420 460 470 490 510 530 580 620 1050 1100 1180 1290 1350 1400
Soundproof Type Dimensions
(LXWXH) m
1530×755×1055 1620×755×1070 1835×800×1155 2000×800×1155 2140×850×1200 2340×950×1520
Weight (KG) 620 630 670 750 710 720 740 790 750 800 940 1610 1700 1750 1890 1950 2000
Notes: (1)Above based on voltage 220/380V.
(2)The weights are approximate and without fuel.
(3)In line with our policy of continuous product development, we reserve the right to change specification without notice.
(4)N=Natural,T=Turbo-charged,T&CAC=Turbocharged and Charge Air Cooled,T&AAC=Turbocharged,Air-Air Cooled,T&AAA=Turbocharged and Air to Air Aftercooled,T&A=Turbocharged,T&I=Turbo &Intercooler,T&LTA=Turbocharged and Low Temperature Aftercooled & Aftercooled.
Rating Definitions
Prime Power Rating
Applicable for supplying electric power in lieu of commercially purchase power. Prime Power applications must be in the form of one of the following.
Unlimited Time Running Prime Power
Prime Power is available for an unlimited number of hours per year in a varible load application. Variable load should not exceed a 70% average of the Prime. 
Power rating during any operating period of 250 hours.The total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload 
capability is available for a period of 1 hour within a 12-hour period of operation. Total operationg time at the 10% overload power shall not exceed 25 hours 
per year.