OPEN-TYPE-DIESEL-GENERATOR-SETS

Product Description

 

GENERATOR SETS POWERED BY FAW ENGINE
















MAIN SPECIFICATION OF DIESEL GENERATOR SETS (50HZ)
GENSET
MODEL
Open type model GDF15 GDF20 GDF25 GDF30 GDF30 GDF30 GDF40 GDF38 GDF50 GDF50 GDF63 GDF63 GDF80 GDF100 GDF125 GDF150 GDF188 GDF225 GDF250 GDF313 GDF338
Soundproof model GDF15S GDF20S GDF25S GDF30S GDF30S GDF30S GDF40S GDF38S GDF50S GDF50S GDF63S GDF63S GDF80S GDF100S GDF125S GDF150S GDF188S GDF225S GDF250S GDF313S GDF338S
Prime output(kVA/kW) 15/12 20/16 25/20 30/24 30/24 30/24 40/32 38/30 50/40 50/40 63/50 63/50 80/64 100/80 125/100 150/120 188/150 225/180 250/200 313/250 338/270
Standby output (kVA/kW) 16.5/13.2 22/17.6 27.5/22 33/26.4 33/26.4 33/26.4 44/35.2 41.8/33 55/44 55/44 68.8/55 68.8/55 88/70 110/88 138/110 176/140 206/165 248/198 275/220 344/275 375/300


DIESEL ENGINE MODEL 4DW81-23D 4DW91-29D 4DW92-35D 4DW92-39D 4DW93-42D 4DX21-45D 4DX21-53D 4DX22-50D 4DX22-65D 4DX23-65D 4DX23-78D 4110/125Z-09D CA4DF2-12D CA6DF2D-14D CA6DF2-17D CA6DF2-19D CA6DL1-24D CA6DL2-27D CA6DL2-30D CA6DM2J-39D CA6DM2J-41D CA6DN1J-45D
ENGINE CHARACTERS Water-cooled,in line,4-stroke,direct injection,wet cylinder liner,1500rpm
Prime Output (KW) 17 21 26 29 31 33 39 37 48 48 57 65 84 96 125 140 176 205 227 287 300 332
Standby Output (KW) 19 23 29 32 34 36 43 41 52.8  53 62.7  72 92 105 138 154 194 226 251 316 330 365
Aspiration N N T T T&I N N T T T&I T&I T T&I T T T&I T&I T&I T&I T&I T&I T&I
NO. of Cylinder 4 6
Bore x Stroke (mm) 85x100 90x100 90x100 90x100 90x100 102*118 102*118 102*118 102*118 102*118 102*118 110*125 110*125 110*115 110*125 110*125 110*135 112*145 112*145 123*155 123*155 131*155
Displacement (L) 2.27  2.54  2.54  2.54  2.54  3.86  3.86  3.86  3.86  3.86  3.86  4.75  4.75  7.13  7.13  7.13  7.70  8.57  8.57  11.04  11.04  12.53 
Compression Ratio 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17:01 17.5:01 17.5:01 17.5:01 17.5:01 17.5:01 18:1
Emission Certification Stage II
Governor Regulation ≤5% ≤3%
Rated Fuel Consumption@100% Load ( g/kWh) 240 240 230 230 216 230 230 220 220 215 215 215 205 202  202  200  196  195  195  195  195  195 
Governor   Mechnical Mechnical Mechnical Electronic Mechnical Mechnical Electronic Mechnical Electronic Mechnical Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic
Alternator Model JDG164D JDG184E JDG184F JDG184G JDG184G JDG184G JDG224C JDG184H JDG224D JDG224D JDG224E JDG224E JDG224GS JDG274C JDG274DS JDG274F JDG274G JDG274J JDG274K JDG314ESS JDG314E JDG314FS
Prime Output (kVA/kW) 16/12.8 22.5/18 27.5/22 31.3/25 31.3/25 31.3/25 42.5/34 37.5/30 50/40 50/40 60/48 60/48 80/64 100/80 120/96 160/128 190/152 230/184 250/200 313/250 350/280 380/304
Power Efficiency 81.00% 84.90% 85.7% 86.6% 86.6% 86.6% 86.6% 86.6% 87.7% 87.7% 88.3% 88.3% 89.8% 89.8% 90.3% 92.0% 92.0% 92.4% 92.5% 93.6% 93.2% 93.4%
CHARACTERS 4 Pole, Rotating Field,Brushless, Self excited,H class insulation,IP22,AVR460/440 ,12 WINDING LEADS.
Voltage Regulation ±1.0% with4% engine governing
Open Type Dimensions
(LXWXH) m
1500x750x1150 1500x750x1150 1600x750x1150 1700x750x1200 1800x750x1300 2000x850x1500 2200x900x1500 2200x900x1600 2200x900x1600 2300x1000x1700 2500x1000x1700 2700x1000x1700 2800x1000x1700
Weight (KG) (2)  550 600 650 700 700 800 820 830 850 880 900 1100 1140 1200 1300 1700 2000 2200 2500
Soundproof Type Dimensions
(LXWXH) m
1890×850×1150 2010×870×1200 2250×950×1300 2260×1010×1490 2410×960×1510 2860×1080×1590 3150×1075×1610 3160×1080×1610 3300×1200×1805 3950×1550×2100 3950×1410×2110
Weight (KG) 800 900 1100 1150 1200 1300 1350 1650 1760 1800 1900 2000 2900 4000 4100 5000
Notes: (1)Above based on voltage 220/380V.
(2)The weights are approximate and without fuel.
(3)In line with our policy of continuous product development, we reserve the right to change specification without notice.
(4)N=Natural,T=Turbo-charged,T&CAC=Turbocharged and Charge Air Cooled,T&AAC=Turbocharged,Air-Air Cooled,T&AAA=Turbocharged and Air to Air Aftercooled,T&A=Turbocharged,T&I=Turbo &Intercooler,T&LTA=Turbocharged and Low Temperature Aftercooled & Aftercooled.
Rating Definitions
Prime Power Rating
Applicable for supplying electric power in lieu of commercially purchase power. Prime Power applications must be in the form of one of the following.
Unlimited Time Running Prime Power
Prime Power is available for an unlimited number of hours per year in a varible load application. Variable load should not exceed a 70% average of the Prime. 
Power rating during any operating period of 250 hours.The total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload 
capability is available for a period of 1 hour within a 12-hour period of operation. Total operationg time at the 10% overload power shall not exceed 25 hours 
per year.