CONTAINERIZED TYPE DIESEL GENERATOR SETS--CUMMINS SERIES
Product Description
GENERATOR SETS POWERED BY CUMMINS ENGINE | |||||||||||
MAIN SPECIFICATION OF DIESEL GENERATOR SETS (50HZ) | |||||||||||
GENSET MODEL | Soundproof model | GDC625S | GDC725S | GDC750S | GDC800S | GDC910S | GDC1000S | GDC1125S | GDC1250S | GDC1375S | GDC1500S |
Prime output(kVA/kW) | 625/500 | 725/580 | 750/600 | 800/640 | 910/728 | 1000/800 | 1125/900 | 1250/1000 | 1375/1100 | 1500/1200 | |
Standby output (kVA/kW) | 687/550 | 800/640 | 825/660 | 880/704 | 1000/800 | 1100/880 | 1250/1000 | 1375/1100 | 1512/1210 | 1650/1320 |
TECHNICAL DATA | |||||||||||
DIESEL ENGINE MODEL | KT38-G | KT38-GA | KTA38-G2 | KTA38-G2B | KTA38-G2A | KTA38-G5 | KTA38-G9 | KTA50-G3 | KTA50-G8 | KTA50-GS8 | |
ENGINE CHARACTERS | Water-cooled, 60° Vee,4-stroke,direct injection,wet cylinder liner,1500rpm | ||||||||||
Prime Output (KW) | 560 | N/A | 664 | 711 | 813 | 880 | N/A | 1097 | 1200 | 1287 | |
Standby Output (KW) | 616 | 711 | 731 | 789 | 895 | 970 | 1089 | 1227 | 1429 | 1429 | |
Aspiration | T&A | T&I | T&A | T<A | |||||||
NO. of Cylinder | 12 | 16 | |||||||||
Bore x Stroke (mm) | 159×159 | ||||||||||
Displacement (L) | 37.8 | 50.3 | |||||||||
Compression Ratio | 15.5 : 1 | 13.9 : 1 | 14.5 : 1 | 13.9 : 0 | 13.9 : 1 | 14.9 : 1 | |||||
Exhaust Gas Temperature (℃) | 521 | 529 | 541 | 477 | 527 | 499 | 529 | 525 | 510 | 510 | |
Rated Fuel Consumption@100% Load (L/h) | 140 | 225 | 167 | 154 | 191 | 209 | 256 | 261 | 289 | 309 | |
Lub Oil Capacity (L) | 135 | 135 | 177 | 204 | 204 | ||||||
Alternator Model | JDG354FS | JDG404B | JDG404B | JDG404C | JDG404D | JDG404E | JDG404F | JDG404G | JDG454B | JDG454C | |
Prime Output (kVA/kW) | 625/500 | 750/600 | 750/600 | 800/640 | 910/728 | 1000/800 | 1125/900 | 1250/1000 | 1400/1120 | 1550/1240 | |
Power Efficiency | 95.0% | 93.2% | 93.2% | 93.6% | 93.5% | 94.2% | 94.6% | 94.8% | 95.2% | 95.6% | |
CHARACTERS | 4 Pole, Rotating Field,Brushless, Self excited,H class insulation,IP22,AVR460/440 ,12 WINDING LEADS. | ||||||||||
Voltage Regulation | ±1.0% with4% engine governing | ||||||||||
Soundproof Type Dimensions (LXWXH) m | 6058x2438x2590 | 40' Standard Container | |||||||||
Weight (KG) | 8500 | 8500 | 8500 | 8700 | 8800 | 9000 | 10000 | 12000 | 13000 | 13000 | |
Notes: (1)Above based on voltage 220/380V. | |||||||||||
(2)The weights are approximate and without fuel. | |||||||||||
(3)In line with our policy of continuous product development, we reserve the right to change specification without notice. | |||||||||||
(4)N=Natural,T=Turbo-charged,T&CAC=Turbocharged and Charge Air Cooled,T&AAC=Turbocharged,Air-Air Cooled,T&AAA=Turbocharged and Air to Air Aftercooled,T&A=Turbocharged,T&I=Turbo &Intercooler,T<A=Turbocharged and Low Temperature Aftercooled & Aftercooled. | |||||||||||
Rating Definitions | |||||||||||
Prime Power Rating | |||||||||||
Applicable for supplying electric power in lieu of commercially purchase power. Prime Power applications must be in the form of one of the following. | |||||||||||
Unlimited Time Running Prime Power | |||||||||||
Prime Power is available for an unlimited number of hours per year in a varible load application. Variable load should not exceed a 70% average of the Prime. | |||||||||||
Power rating during any operating period of 250 hours.The total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload | |||||||||||
capability is available for a period of 1 hour within a 12-hour period of operation. Total operationg time at the 10% overload power shall not exceed 25 hours | |||||||||||
per year. |